Abstract
Remarkable sensitivity and exquisite frequency selectivity are hallmarks of mammalian hearing, but their underlying mechanisms remain unclear. Cochlear insults and hearing disorders that decrease sensitivity also tend to broaden tuning, suggesting that these properties are linked. However, a recently developed mouse model of genetically altered hearing (Tectb−/−) shows decreased sensitivity and sharper frequency selectivity. In this paper, we show that the Tectb mutation reduces the spatial extent and propagation velocity of tectorial membrane (TM) travelling waves and that these changes in wave propagation are likely to account for all of the hearing abnormalities associated with the mutation. By reducing the spatial extent of TM waves, the Tectb mutation decreases the spread of excitation and thereby increases frequency selectivity. Furthermore, the change in TM wave velocity reduces the number of hair cells that effectively couple energy to the basilar membrane, which reduces sensitivity. These results highlight the importance of TM waves in hearing.
Similar content being viewed by others
Introduction
Our ability to detect and analyse sounds is fundamental to our natural ability to communicate with each other and to navigate through acoustically rich environments. A variety of mechanisms have been demonstrated whereby 'cochlear amplification'1,2,3,4,5,6,7,8 can effectively reduce viscous loss of energy (damping) and thereby increase both sensitivity and frequency selectivity, suggesting that sensitivity and frequency resolution are inextricably linked1,2,3. However, the direct coupling of these remarkable properties is challenged by a recent study of a mouse model of genetically altered hearing (Tectb−/−) with decreased sensitivity and strikingly sharpened frequency selectivity9,10,11.
Tectb encodes β-tectorin, a glycoprotein that is localized to the tectorial membrane (TM) (ref. 12) and the absence of which leads to disruption of the TM's core structure and to significant changes in cochlear function9. Targeted deletion of β-tectorin in Tectb−/− mice reduces sensitivity by ∼10 dB SPL while simultaneously increasing the sharpness of tuning by about a factor of 2–3 at mid to high frequencies; at low frequencies, sensitivity is markedly reduced (∼50 dB SPL) (ref. 9). These physiological changes cannot be explained by a change in effective damping or by any other mechanism that links sharpened frequency selectivity to increased sensitivity.
Here, we show that differences in the wave properties of TMs of Tectb−/− and wild-type mice can account for all of the unexplained hearing properties of Tectb−/− mice. According to this mechanism, TM waves coordinate the activities of multiple outer hair cells (OHCs) and thereby have an important role in determining both sensitivity and frequency selectivity of cochlear amplification. At mid and high frequencies, the Tectb mutation reduces the spatial extent and velocity of TM waves, which can reduce cochlear sensitivity while simultaneously sharpening frequency selectivity. At low frequencies, the even greater reduction in TM wave velocity produces an even greater loss of sensitivity. These findings demonstrate mechanisms by which TM waves moderate a balance between sensitivity and exquisite frequency selectivity in mammalian hearing.
Results
TM travelling waves in Tectb−/− and wild-type mice
To determine how the loss of β-tectorin affects TM waves, we investigated longitudinally propagating waves of radial motion along Tectb−/− and wild-type TMs (see Methods section). TM segments were isolated from the cochleae and suspended between two supports in a fluid-filled wave chamber (Fig. 1a). Sinusoidal forces applied in the radial direction at one support generated waves that propagated longitudinally along the TM13. These waves were of nanometre scale in amplitude and observed over a broad range of frequencies (1–18 kHz). An optical imaging system using stroboscopic illumination tracked displacement amplitude and phase at multiple points on the surface of the TM. Complex exponentials were fit to the waveforms over 16 phase cycles. These fits contain two free parameters: wavelength (λ; distance the wave travels while going through a full cycle of motion) and wave decay constant (σ ; distance the wave travels before dissipating by a factor of e in amplitude) (Fig. 1b).
Decay constants and wavelengths are reduced in Tectb−/− TMs
We captured snapshots of radial motion along TM segments at one phase of a periodic driving signal (Fig. 1c,d). At 18 kHz, the waveform of Tectb−/− TM segments excised from the middle to the basal third of the cochlea (referred to as 'basal Tectb−/− TM') had shorter wave decay constants (reduced by ∼55%) and wavelengths (reduced by ∼20%) than did basal wild-type TMs (Fig. 1c). Across the apical segments, Tectb−/− TMs had considerably shorter wave decay constants (reduced by ∼75%) and wavelengths (reduced by ∼60%) compared with apical wild-type TMs, particularly at low frequencies (Fig. 1d).
Wave decay constant (σ) data were pooled across multiple basal and apical TM segments, further highlighting significant differences between Tectb−/− and wild-type TM samples (Fig. 2a,b). Across basal segments, Tectb−/− TMs (11 measurements) had a range of σ-values between 65 and 180 μm at high frequencies (>10 kHz), whereas the range of σ -values for wild-type TMs (16 measurements) were all ≥185 μm (Fig. 2a). Across apical segments, the σ -values for Tectb−/− TMs (19 measurements; 45–220 μm) were significantly lower than those for wild-type TMs (15 measurements; ≥190 μm) at frequencies ≥2 kHz (Fig. 2b).
The reduction in wave decay constants in Tectb−/− TMs (Fig. 2a,b) correlates with previously reported reductions in the bandwidth of frequency tuning curves in Tectb−/− mice9. The bandwidth of frequency tuning at one cochlear location can be related to the spatial extent of tuning at one stimulus frequency by applying local scaling symmetry (the idea that frequency tuning curves at nearby characteristic frequencies (CFs) are identical when scaled by fCF)14,15 and then mapping CFs to best cochlear locations16. Using this technique, we calculate a 30–50% reduction in spatial bandwidths at the 10 and 20-kHz best locations in Tectb−/− mice with respect to wild types, which is comparable to the reduction in the extent of TM waves in Tectb−/− mice at 10 and 20 kHz (Fig. 2a,b).
Wave propagation velocities are reduced in Tectb−/− TMs
We computed the velocity of wave propagation (vs) over a range of stimulus frequencies as the product of frequency and wavelength (2πδx/δϕ), where δϕ is the phase accumulation between two sites along the TM (Fig. 3a,b) and δx is the longitudinal distance separating those sites. Propagation velocities were generally smaller in Tectb−/− TMs than in wild-type TMs. Although these differences were smaller in basal segments (Fig. 4a) than in apical segments (Fig. 4b), the differences were statistically significant in both regions.
TM material properties account for changes in waves
The frequency-dependent wave properties of the TM provide information about the underlying TM material properties. For example, the velocity vs of pure shear waves in an infinite, isotropic, viscoelastic material depends on the shear storage modulus G' (which characterizes elastic energy stored during parallel motions of the surfaces of a deformable body), the shear viscosity η (which characterizes dissipation of energy) and density ρ, as follows:
where ω is the angular frequency of vibration13,17,18. We can use this equation to estimate the material properties of the TM by finding the values of G′ and η to best fit the measured values of vs (density ρ is taken to be that of water). To account for boundary conditions of the wave chamber and attenuation of wave motion (wave decay constant), we analysed a finite difference model that consists of a longitudinally distributed series of masses coupled to viscous and elastic elements13. Sinusoidal stimuli applied to one end of this model of the TM launched travelling waves that were similar to those measured experimentally in wild-type and Tectb−/− TMs. Best fit estimates of the material properties (mean±s.d.) of basal Tectb−/− TMs (G′=18±1 kPa, η=0.17±0.06 Pa·s; n=3 TM preparations) were smaller than those of wild-type TMs (G′=42±10 kPa, η=0.23±0.07 Pa·s; n=7 TM preparations). For apical TMs, the material properties of Tectb−/− TMs (G′=1±0.1 kPa, η=0.12±0.13 Pa·s; n=3 TM preparations) were also reduced with respect to wild-type TMs (G′=14±4 kPa, η=0.21±0.12 Pa·s; n=4 TM preparations). Thus, the shear storage modulus G′ was reduced by factors of 2.3 (basal) and 14 (apical) in the TMs of Tectb−/− mutants relative to wild types, whereas viscosity changes were small. We attribute the change in shear storage modulus to disruption of the TM's striated sheet matrix (caused by the absence of β-tectorin), which makes up the core structure of the TM and in which the radial collagen fibres are embedded. Without the striated sheet matrix, the radial collagen fibres lack uniform layout and structural support, thus giving rise to reduced shear storage modulus.
In vivo, TM is coupled to hair bundles, attached at the spiral limbus and bound below by a narrow subtectorial fluid space. We tested the effects of these cochlear loads on TM wave propagation in Tectb−/− mice using a finite difference model (Supplementary Fig. S1a). We modelled OHC hair bundles as springs, the limbal attachment as an elastic solid and the subtectorial space as a viscous fluid. For physically plausible values of these parameters, the effects of these cochlear loads on wave motion were small (Supplementary Fig. S1b–d). Only the limbal attachment had a significant effect on the waves in wild-type and Tectb−/− mice; this effect was to increase the wavelength (by <15%).
Discussion
Results in this study demonstrate that the Tectb mutation alters TM wave properties. These changes in wave properties provide insight into the hearing abnormalities of Tectb−/− mice, which are otherwise difficult to understand. Previously, it was shown that the Tectb mutation leads to sharpened tuning and decreased sensitivity at mid to high frequencies of hearing, and markedly reduced sensitivity at low frequencies9. Taken together, these differences in physiological response cannot be explained by a change in effective damping or a simple attenuation in amplification mechanisms. However, this combination of hearing abnormalities is consistent with our measured changes in TM wave velocity and decay constants, as described in the following paragraphs.
Because TM waves extend over significant longitudinal distances, these waves would tend to coordinate the activities of many sensory receptors (∼75 to 150), spanning regions (∼200 to 400 μm) that correspond to frequencies within an octave of the best frequency19. This mechanism could increase the number of OHCs that participate in amplification of narrow-band stimuli and thereby increase cochlear sensitivity by increasing the effective gain of the amplification. The moderate (but statistically significant) decrease in the extent of TM waves in Tectb−/− mice (Fig. 2a) could lead to fewer hair cells working in synchrony, thereby causing a moderate decrease in sensitivity (∼10 dB SPL) at mid to high frequencies9,10,11. Moreover, such a reduction in the coordinated activity of hair cells in Tectb−/− mice would simultaneously lead to an increase in frequency selectivity by reducing the longitudinal spread of excitation, allowing adjacent regions of the cochlea to vibrate at their own local best frequencies. The shorter wave decay constants (∼55% reduction) in Tectb−/− mice (Fig. 5) would lead to sharpened frequency selectivity, in good agreement with the factor of ∼2 increase in sharpness of tuning (Q10 dB) at mid to high frequencies9,10,11. The increased frequency selectivity in the Tectb−/− mutants might be regarded as an improvement in hearing. However, there is a fundamental trade-off between resolution in frequency and resolution in time, and this trade-off implies that increasing frequency selectivity decreases temporal resolution. By this logic, increasing frequency resolution could result in impairment of temporal resolution. The substantial role of longitudinal coupling20,21,22,23,24,25 in controlling cochlear tuning and timing is consistent with a recently published cochlear model18.
Our results show that the absence of β-tectorin also slows the velocity of TM waves (Fig. 4a,b). This reduction in velocity could have important implications for cochlear amplification. The concept that cochlear amplification could arise from the interaction of two propagating waves was first described by Hubbard26, who showed that wave amplification arises when the velocities of two waves are matched. The small change in TM wave velocity (by a factor of 1.66) that results along basal sections of the cochlea in Tectb−/− mice (Fig. 4a) could thereby contribute to the small loss of sensitivity (∼10 dB SPL) at mid to high frequencies that has been reported for these mice9. More importantly, the large change in apical TM wave velocity (by up to a factor of ∼6.25; Fig. 4b) could cause a substantial decrease in sensitivity (∼50 dB SPL), virtually eliminating amplification at low frequencies.
In summary, TM waves constitute a new mechanism that is complementary to those in conventional theories, in which increased gain tends to sharpen tuning20. Such a complementary mechanism may be essential for attaining high sensitivity without suffering poor temporal resolution that would result if frequency selectivity were increased excessively. By facilitating high gain with reduced frequency selectivity, TM waves provide a mechanism that functions to balance the relative advantages of sensitivity, frequency selectivity and temporal resolution—all of which are hallmarks of mammalian hearing.
Methods
Isolated TM preparation
TM segments were excised from the cochleae of adult (15–30 g, 4–8 weeks old) Tectb−/− (strain 129SvEv/C57BL6J) and wild-type mice (strains 129SvEv/C57BL6J, B6129F1 and CD-1). No strain-dependent differences were found. Segments (typically 0.5–1 mm in longitudinal length) were isolated from the organ with a sterilized eyelash probe and placed in a fresh artificial endolymph bath (containing 174 mM KCl, 5 mM HEPES, 3 mM dextrose, 2 mM NaCl and 0.02 mM CaCl2) in preparation for wave motion measurements13,27. TM segments from the low-frequency regions were classified as 'apical' (0–30% from the apex) and those from mid to high frequency regions of the cochlea were classified as 'basal' (40–80% from the apex)16,28. The care and use of animals in this study were approved by the Massachusetts Institute of Technology Committee on Animal Care.
Wave motion measurements
Isolated segments of Tectb−/− and wild-type TMs were suspended13 between the supports of a wave chamber (Fig. 1a). One support was attached with epoxy to a piezo-electric actuator (Thorlabs) and loosely coupled to the underlying glass slide. Motion of this vibrating support was examined to ensure uniform sinusoidal motion before each experiment. The second stationary support was firmly fixed to the glass slide with epoxy. To position TM samples in this experiment chamber, the surfaces of the supports were coated with ∼0.3 μl of tissue adhesive (Cell Tak; Collaborative Research). Artificial endolymph solution was then perfused in the region of the supports and over the adhesive. The TM segment was then injected into this medium with a small glass-tipped pipette. We used a sterilized eyelash probe to gently manoeuvre the TM into position between the supports. The TM was positioned so that its radial fibres were parallel to the motion of the vibrating support. The suspended region of the TM was approximately 200–300 μm above the surface of the underlying glass slide. The entire suspended TM structure was imaged with a transmitted-light microscope13.
Optical imaging system
The optical system consisted of ×20 and ×40 water immersion objectives (Zeiss Axioplan) with a 0.5 numerical aperture and a transmitted-light condenser (0.8 numerical aperture). Images were collected with a 12 bit, 1024×1024 pixel CCD camera (CAD7-1024A, Dalsa) by strobing the light-emitting diode. The TM segment was illuminated at 16 evenly spaced stimulus phases over several stimulus cycles. The collected images were analysed to determine the first eight harmonics of the periodic motion. We computed the magnitude and phase of radial displacement from the spatial and temporal brightness gradients in the images29,30.
Additional information
How to cite this article: Ghaffari, R. et al. Tectorial membrane travelling waves underlie abnormal hearing in Tectb mutant mice. Nat. Commun. 1:96 doi: 10.1038/ncomms1094 (2010).
References
Gold, T. Hearing II. The physical basis of the action of the cochlea. Proc. R. Soc. Lond. B. Biol. Sci. 135, 492–498 (1948).
Robles, L. & Ruggero, M. A. Mechanics of the mammalian cochlea. Physiol. Rev. 81, 1305–1352 (2001).
Ashmore, J. Cochlear outer hair cell motility. Physiol. Rev. 88, 173–210 (2008).
Brownell, W. E., Bader, C. R., Bertrand, D. & de Ribaupierre, Y. Evoked mechanical responses of isolated cochlear outer hair cells. Science 227, 194–196 (1985).
Liberman, M. C., Gao, J., He, D. Z., Wu, X., Jia, S. & Zuo, J. Prestin is required for electromotility of the outer hair cell and for the cochlear amplifier. Nature 419, 300–304 (2002).
Kennedy, H. J., Crawford, A. C. & Fettiplace, R. Force generation by mammalian hair bundles supports a role in cochlear amplification. Nature 433, 880–883 (2005).
Chan, D. K. & Hudspeth, A. J. Ca2+ current driven nonlinear amplification by the mammalian cochlea in vitro. Nat. Neurosci. 8, 149–155 (2005).
Kennedy, H. J., Evans, M. G., Crawford, A. C. & Fettiplace, R. Depolarization of cochlear outer hair cells evokes active hair bundle motion by two mechanisms. J. Neurosci. 26, 2757–2766 (2006).
Russell, I. J. et al. Sharpened cochlear tuning in a mouse with a genetically modified tectorial membrane. Nat. Neurosci. 10, 215–223 (2007).
Lukashkin, A. N., Lukashkina, V. A., Richardson, G. P. & Russell, I. J. in The Biophysics of Hearing (eds Cooper, N. P. & Kemp, K. T.) (World Scientific Publishing, 2009).
Richardson, G. P., Lukashkin, A. N. & Russell, I. J. The tectorial membrane: one slice of a complex cochlear sandwich. Curr. Opin. Otolaryngol. Head Neck Surg. 16, 458–464 (2008).
Goodyear, R. J. & Richardson, G. P. Extracellular matrices associated with the apical surfaces of sensory epithelia in the inner ear: molecular and structural diversity. J. Neurobiol. 53, 212–227 (2002).
Ghaffari, R., Aranyosi, A. J. & Freeman, D. M. Longitudinally propagating traveling waves of the mammalian tectorial membrane. Proc. Natl Acad. Sci. USA 104, 16510–16515 (2007).
Kiang, N. Y. S. & Moxon, E. C. Tails of tuning curves of auditory-nerve fibers. J. Acoust. Soc. Am. 55, 620–630 (1974).
Shera, C. A., Talmadge, C. L. & Tubis, A. Interrelations among distortion-product phase-gradient delays: their connection to scaling symmetry and its breaking. J. Acoust. Soc. Am. 108, 2933–2948 (2000).
Müller, M., von Hünerbein, K., Hoidis, S. & Smolders, J. W. A physiological place-frequency map of the cochlea in the CBA/J mouse. Hear. Res. 202, 63–73 (2005).
Chen, S., Fatemi, M. & Greenleaf, J. F. Quantifying elasticity and viscosity from measurement of shear wave speed dispersion. J. Acoust. Soc. Am. 115, 2781–2785 (2004).
Meaud, J. & Grosh, K. The effect of tectorial membrane and basilar membrane longitudinal coupling in cochlear mechanics. J. Acoust. Soc. Am. 127, 1411–1421 (2010).
Rhode, W. S. & Recio, A. Study of mechanical motions in the basal region of the chinchilla cochlea. J. Acoust. Soc. Am. 107, 3317–3332 (2000).
de Boer, E. in The Cochlea (eds Dallas, P., Popper, A. N. & Fay, R. R.) (Springer-Verlag, 1996).
Steele, C. R., Baker, G., Tolomeo, J. & Zetes, D. in Biophysics of Hair Cell Sensory Systems (ed. Gummer, A. W.) (World Scientific, 1993).
Zwislocki, J. J. & Kletsky, E. J. Tectorial membrane: a possible effect on frequency analysis in the cochlea. Science 204, 639–641 (1979).
Geisler, C. D. & Sang, C. A cochlear model using feed-forward outer-hair-cell forces. Hear. Res. 86, 132–146 (1995).
Naidu, R. C. & Mountain, D. C. Longitudinal coupling in the basilar membrane. J. Assoc. Res. Otolaryngol. 2, 257–267 (2001).
Karavitaki, K. D. & Mountain, D. C. Evidence for outer hair cell driven oscillatory fluid flow in the tunnel of Corti. Biophys. J. 92, 3284–3293 (2007).
Hubbard, A. A traveling-wave amplifier model of the cochlea. Science 259, 68–71 (1993).
Shah, D. M., Freeman, D. M. & Weiss, T. F. The osmotic response of the isolated, unfixed mouse tectorial membrane to isosmotic solutions: effect of Na+, K+, and Ca2+ concentration. Hear. Res. 87, 187–207 (1995).
Viberg, A. & Canlon, B. The guide to plotting a cochleogram. Hear Res. 197, 1–10 (2004).
Davis, C. Q. & Freeman, D. M. Using a light microscope to measure motions with nanometer accuracy. Opt. Eng. 37, 1299–1304 (1998).
Aranyosi, A. J. & Freeman, D. M. Sound-induced motions of individual cochlear hair bundles. Biophys. J. 87, 3536–3546 (2004).
Acknowledgements
We thank J.J. Guinan, C.A. Shera, A.J. Grodzinsky, S.C. Page and S. Farrahi for helpful discussions and comments on the manuscript. This research was supported by the National Institutes of Health Grant R01-DC000238. R.G. was supported in part by a training grant from the National Institutes of Health to the Speech and Hearing Bioscience and Technology Program in the Harvard–MIT Division of Health Sciences and Technology. G.P.R. was supported by Wellcome Trust Grants 071394/Z/03/Z and 087737.
Author information
Authors and Affiliations
Contributions
R.G., D.M.F., A.J.A. and G.P.R. designed the research. R.G. conducted the experiments. R.G. and A.J.A. analysed the data. G.P.R. provided the genetically modified mice. R.G., D.M.F. and A.J.A. wrote the paper.
Corresponding author
Ethics declarations
Competing interests
The authors declare no competing financial interests.
Supplementary information
Supplementary Figure
Supplementary Figure S1 (PDF 136 kb)
Rights and permissions
This work is licensed under a Creative Commons Attribution-NonCommercial-Share Alike 3.0 Unported License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/3.0/
About this article
Cite this article
Ghaffari, R., Aranyosi, A., Richardson, G. et al. Tectorial membrane travelling waves underlie abnormal hearing in Tectb mutant mice. Nat Commun 1, 96 (2010). https://doi.org/10.1038/ncomms1094
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/ncomms1094
This article is cited by
-
Inner hair cell stereocilia are embedded in the tectorial membrane
Nature Communications (2021)
-
GATA3 maintains the quiescent state of cochlear supporting cells by regulating p27kip1
Scientific Reports (2021)
-
Two-tone distortion in reticular lamina vibration of the living cochlea
Communications Biology (2020)
-
Reducing tectorial membrane viscoelasticity enhances spontaneous otoacoustic emissions and compromises the detection of low level sound
Scientific Reports (2019)
-
A connexin30 mutation rescues hearing and reveals roles for gap junctions in cochlear amplification and micromechanics
Nature Communications (2017)
Comments
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.