Abstract
Ozone emissions were measured above a “personal air purifier” (PAP) designed to be worn on a lapel, shirt pocket, or neck strap. The device is being marketed as a negative ion generator that purifies the air. However, it also produces ozone within the person's immediate breathing zone. In order to assess worst-case potential human exposure to ozone at the mouth and nose, we measured ozone concentrations in separate tests at 1, 3, 5, and 6 in. above each of two PAPs in a closed office. One PAP was new, and one had been used slightly for 3 months. Temperature, relative humidity, atmospheric pressure, room ozone concentration, and outdoor ozone concentration also were measured concurrently during the tests. Average ozone levels measured directly above the individual PAPs ranged from 65–71 ppb at 6 in. above the device to 268–389 ppb at 1 in. above the device. Ozone emission rates from the PAPs were estimated to be 1.7–1.9 µg/minute. When house dust was sprinkled on the top grid of the PAPs, one showed an initial peak of 522 ppb ozone at 1 in., and then returned to the 200–400 ppb range. Room ozone levels increased by only 0–5 ppb during the tests. Even when two PAPs were left operating over a weekend, room ozone levels did not noticeably increase beyond background room ozone levels. These results indicate that this “PAP,” even without significant background ozone, can potentially elevate the user's exposures to ozone levels greater than the health-based air quality standards for outdoor air in California (0.09 ppm, 1-hour average) and the United States (0.08 ppm, 8-hour average).
This is a preview of subscription content, access via your institution
Access options
Subscribe to this journal
Receive 6 print issues and online access
$259.00 per year
only $43.17 per issue
Buy this article
- Purchase on Springer Link
- Instant access to full article PDF
Prices may be subject to local taxes which are calculated during checkout
Similar content being viewed by others
Author information
Authors and Affiliations
Corresponding author
Additional information
Disclaimer: The statements and conclusions in this report are those of the authors and not necessarily those of the California Air Resources Board. The mention of commercial products, their source, or their use in connection with material reported herein is not to be construed as either actual or implied endorsement of such products.
Presented at: ISEA 7th Annual Meeting, November 2-5, 1997, Research Triangle Park, NC.
Rights and permissions
About this article
Cite this article
PHILLIPS, T., BLOUDOFF, D., JENKINS, P. et al. Ozone emissions from a “personal air purifier”,. J Expo Sci Environ Epidemiol 9, 594–601 (1999). https://doi.org/10.1038/sj.jea.7500005
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1038/sj.jea.7500005